Hot Water Tanks, Pumps, Accessories and More

Boiler Nova tank:

Made in Italy

Water capacity Diameter Height Insulation Lower Coil Upper Coil Work. Pressure
السعة  قطر ارتفاع العزل مبادل سفلي مبادل علوي الضغط التشغيلي  
Ltr. mm mm mm m2 m2 Bar
200 600 1215 50 1.5 0.5 10
300 600 1615 50 1.8 1.1 10
500 750 1690 50 2.2 1.3 10
1000 990 2105 100 3 1.6 10
1500 1200 2185 100 3.4 >1.8 8
2000 1300 2470 100 4.6 2.8 8
Resistance 2000W 230V 1.1/2 Copper

 

 

Warranty applies only if an expansion tank and safety valve are installed on the sanitary hot water side.

الكفالة سارية المفعول فقط عند تركيب خزان تمدد مغلق و صمام امان في دارة الماء الصحية الساخنة

Wilo Pumps:

Made in Germany

 

 

Pump Power W. Speeds Body Length without Connection Union
STAR RS  30/4 – EM 48 3 180 1 1/4″ or 1 1/2″ F
STAR RS  30/6 – EM 84 3 180 1 1/4″ or 1 1/2″ F
STAR RS  30/7 – EM 132 3 180 1 1/4″ or 1 1/2″ F
STAR RS  30/8 – EM 151 3 180 1 1/4″ or 1 1/2″ F
TOP RL 30/6.5 – EM 245 3 180 1 1/4″ or 1 1/2″ F

 

TOP-S  30/7    – EM 195 3 180 1 1/4″ or 1 1/2″ F

 

TOP-S  30/10 – EM 390 3 180 1 1/4″ or 1 1/2″ F

 

Sanitary hot water Bronze circulator

 

 

Pump Power W. Speeds Body Length without Connection Union
STAR-Z 20/1 38 1 140 1/2″ F
STAR-Z 25/2 49 1 180 1″ F
STAR-Z 20/4 71 3 150 3/4″ F
STAR-Z 25/6 99 3 180 1″ F
STAR-Z 20/7 146 3 150 3/4″ F
TOP Z 30/7 165 3 180 1 1/4″ or 1 1/2″ F
TOP Z 30/10 335 3 180 1 1/4″ or 1 1/2″ F

 

Home booster with built in flow switch

 

 

Type Work. Temp. Power Max Head Max Flow Connection
Suction Discharge
PB-088 EA (Flow switch included) 80 140 9 35 1/2″ 1/2″
PB-201EA (Flow switch included) 80 340 16 55 1″ 1″
PB-400 EA (Flow switch included) 80 550 20 75 11/4″ 11/4″

DIFFERENTIAL THERMOCONTROL – (DTHC/S)

Electronic Control

 

Description
– Temperature reader and differential thermocontrol
– Adjustable temperature settings by front keypad
– Defrost mode to prevent freezing of solar panels
– Wide temperature range and control
– Modular housing suitable for mounting on
– 35mm DIN rail (EN 50022)

 

User interface
– Press on the Set button to access the setup menu
– Use the ‘UP” & “Down” buttons to scroll menu list :
– d H : large difference between sensors
– d L : small difference between sensors
– d F : defrost mode (-10′ C up to +10’ C)
– Ed : exit menu
To make an adjustment to one of these parameters :
– Press on the Set button in front of the displayed parameter
– Use the “UP” & “Down” buttons to make the adjustment
– Press again on the Set button to exit the selected parameter

o Defrost mode : the relay will energize when the upper sensor
reaches the temperature set in defrost with a hysteresis of 3′ C
o To read the upper sensor temperature, press on the “UP” button
o L 0 : Temperature lower then -30′ C
o HI : Temperature higher then 99 ‘C
0 U : Upper sensor open circuit
o S U : Upper sensor short circuit
o S L : Lower sensor short circuit
0 L : Lower sensor open circuit

 

Technical data
– Power supply:
175 – 245VAC (50/60Hz)


Control action:
ON f OFF type ; Based on Microchip PIC microcontroller
Temperature is indicated on a 7segment 1f2″ dual display in °C
The output status is indicated with bright-red LEOs


Control output: available
Relay control with 1 (standard) or 2 changeover output contacts:
Max switching voltage : 277 VAC f 30 VDC
Max switching current : 10A for resistive load
Max switching power : 2770VA 1/2Hp


Display range:
Min -30′ C up to Max +99′ C


Accuracy:
0.2% full scale ±1 digit


Ambient conditions:
Indoor use only ; -30 -70°C (-22 -158 °F) ; < 90% RH non-condensing


Power consumption:
< 6VA


Dimensions:
90 x 54 x 58 mm (3 .5″ H x 2.1 ” W x 2.3″ D)


Housing & Enclosure:
‘” 235g (0.52 Ib) ; Degree of protection: IP40
Flame retardant plastic modular housing with transparent red snap-in
cover, for mounting on 35mm DIN rail (EN 50022)


Sensors included:
NTC thermistor ; 10 KO @ 25°C (7r F) ± 0.2°C
6.012) x 50 L mm , stainless steel, 135°C max applicable temperature
N.B. DO NOT MERGE THE SENSOR NAKED IN LIQUID

Water heater element immersion type

1000W-1500W-2000W-2500W.

 


Water heater element (resistance) Screw type long

1000W-1500W-2000W-2500W.

 

Anode Magnesium

TK7 controller

  • Power Off Memory
  • Water Temperature Preset
  • Intelligent Heating
  • Water Insufficient Alert
  • Leakage Protection
  • Constant Heating
  • Pipe Warm Keeping
  • Water Level Preset
  • Intelligent Water Loading
  • Auto Water Loading
  • Low Pressure Water Loading
  • Constant Water Level Loading
  • Manual Control
  • All Weather Water Supply
  • Auto Control Boosting Pump

SubTank 4L-20L

 

4L to 100 Litrs
-10c/+110c
10 Bar
Factory Precharge 2.5 Car